Linear Electromagnetic Propulsion System for Smart-Compound Logistics

Final Year Project — a linear induction motor shuttle designed, simulated and built

Design and Analysis of a Linear Electromagnetic Propulsion System for Internal Logistics Transport in Smart Compounds

  • Gold Award — 2nd Open International Innovations Challenge (OpIIC 2026)
  • 4th place (Consolation Prize) — BEM Young Engineering Innovation Trophy (NUET)
  • Silver Award — 7th Digitalised International Invention, Innovation & Design (DIIID)
  • Paper accepted — ICEESE 2026 (#1571335201)
Top view of the assembled linear machine on its printed base
Top view of the assembled linear machine on its printed base

What

A single-sided linear induction motor (SLIM) shuttle for moving goods inside industrial compounds with no rotating drivetrain — no gearbox, no belts, no wheel traction limit — sized for a 200 kg payload at 3 m/s.

How

Full-scale design. An 8-pole, 48-slot primary measuring 640 × 160 mm with 26 turns per coil (raised from 20 during design iteration to lift thrust to requirement, taking slot fill to 0.49), an aluminium secondary on mild-steel back iron, and a 2 mm mechanical air gap.

Simulation became a project in itself. The inherited ANSYS Maxwell 2D transient model was audited and found to carry eight distinct errors: a 100 mm motion-band stroke limit that halted travel at 33 ms of a 160 ms run, a 1 ms time step instead of the documented 0.4 ms, force parameters assigned only to the primary core with all 48 coils excluded from the calculation, eddy effects disabled on the secondary steel, 31 conductors per coil instead of 20, 18 A peak entered where 18 A rms was intended, a 13 mm slot pitch instead of 13.333 mm, and a 5 mm mechanical gap. The corrected model was rebuilt from scratch through an IronPython script for AEDT 2025 R2 — winding excitation, coil terminals, phase assignment, motion band and force plotting — working around a platform quirk where oDesign.ChangeProperty calls fail silently and certain properties must be edited through the GUI.

Supporting design work in AutoCAD (a 3D REVOLVE script for the 76 mm polyurethane skate wheels, cable cross-sections, the secondary reaction plate) and a CadQuery-generated 10-component STEP assembly, plus an interactive Three.js model with exploded, x-ray and lid-toggle views.

Prototype. A scaled 4-pole, 24-slot, 320 × 100 mm unit: 40 turns per coil of 0.8 mm enamelled copper on M19/50W470 silicon steel laminations, 3 mm air gap, a PETG carriage on ABEC-9 bearings, driven from a VFD. Lab supply constraints forced testing at 50 Hz against a 25 Hz design point, and the frequency mismatch was analysed explicitly rather than set aside.

Outcome

FEA gave a mean thrust of 219 N against a 218.7 N requirement, with a 267 N starting peak, 168 mT peak air-gap flux density, −816 N normal force (a 3.7:1 ratio), 410 W secondary loss, 451 W copper loss at 75 °C, 1.14 kW input power, 0.46 power factor and 41% efficiency.

The prototype produced 2.26 N standstill thrust at 3.5 A — 75% of the FEA prediction at the same operating point — and transported its 2 kg design payload at 0.128 m/s on 3.0 A, with insulation resistance of 4.5–18.4 GΩ at 1.1 kV.

The gap between the two was traced to transverse edge effect and a larger effective air gap, which produced the project's most important and most defensible conclusion: the 2D model represents an upper bound on achievable thrust, not a conservative floor — reversing the assumption carried in the earlier report.

Recognition: 4th place (Consolation Prize) at the BEM Young Engineering Innovation Trophy (NUET), a Silver Award at the 7th DIIID, and a technical paper accepted at ICEESE 2026. Dissertation signed and viva presented.