Smart Tilting & Solar Panel Cleaner

Automated cleaning and sun-tracking prototype that raised panel output by over 4%

Finished prototype tested outdoors in sunlight
Finished prototype tested outdoors in sunlight

What

A single mechatronic assembly that both cleans a photovoltaic panel and tilts it through a daily sun-tracking cycle. The target was soiling loss, which the team's literature base put at 21.6% of power output (Lasfar, 2021), a 30% drop in conversion efficiency at 10 g/m² dust density (Chen, 2019), and 5.92% monthly degradation measured on UTP's own R&D building roof (Sulaiman, 2018) — an order of magnitude worse than the panels' natural degradation.

The project ran over two semesters: ETP I produced the design-thinking study and extended proposal, ETP II built and tested the prototype.

How

A full design-thinking cycle — a user survey of homeowners and operators found fall risk during manual cleaning at height to be the dominant concern — carried through to a laser-cut acrylic and 3D-printed PLA prototype.

Cleaning axis. A rack-and-pinion carriage carrying brushes and wipers, driven by a servo and fed from a tank by a relay-switched water pump. Traverse time was calculated at 35.7 s per pass from the servo rate (0.2 s/60°), a 10 mm per revolution pinion and a 300 mm span. Rack thickness was sized from the mid-span bending moment (M = FL/4 = 735.75 N·mm) against PLA's 60 MPa tensile strength, giving h ≈ 1.92 mm. Consumption works out to 0.143 L of water plus 0.143 L of cleaning agent per 71.4 s cycle. The cleaning head doubles as a funnel that harvests rainwater back into the tank.

Tilting axis. A linear actuator through an L298N H-bridge drives the 0°–22° elevation change, while a servo on the azimuth platform steps 0°→180° across the day and returns overnight. Both were implemented as a timed state machine in Arduino C++ (Tilting.ino, cleaning.ino), with the panel oriented south for the northern-hemisphere site.

My scope covered all electrical components, the solar tilt-angle calculations and both firmware sketches, alongside coordinating the seven-person team across electrical, mechanical, chemical, petroleum and computer engineering.

Outcome

A working prototype built for RM290 that eliminated manual cleaning cost entirely and lifted monthly panel performance by over 4% from automated cleaning alone, with additional gain from tilting. Delivered as a final report, e-poster and prototype demonstration video.